Initial Operation
The examples below show how to turn off the laser light source on the sensor.
WRREC_DB
1
0
REQ :=
Enable-Flag
ID :=
273
INDEX :=
0x2600
Objekt Index
LEN :=
21
8 Byte + Data Length
RECORD :=
DONE =>
BUSY =>
Status/Result Output
ERROR =>
STATUS =>
Fig. 15 SPS write command with 8 Byte prefix to turn off the laser ligth source on the sensor
RDREC_DB
REQ :=
1
0
ID :=
273
INDEX :=
0x2600
LEN :=
13
RECORD =>
VALID =>
BUSY =>
ERROR =>
Status/Result Output
STATUS =>
LEN =>
Fig. 16 SPS read command to turn off the laser light source on the sensor
IF2035-PROFINET
HW-ID
Write-Header (8 Byte)
0
0 0x01 0 0x0d 0
Enable-Flag
HW-ID
Objekt Index
Data Length
'L' 'A' 'S' 'E' 'R' 'P'
Command: "LASERPOW OFF\n"
'L' 'A' 'S' 'E' 'R' 'P' 'O' 'W' 0x20 'O'
Command: "LASERPOW OFF\n"
0
0
'L' 'A' 'S' 'E' 'R' 'P' 'O' 'W' 0x20 'O'
'O' 'W'
0x20
'O' 'F' 'F' 0x0A
'F'
'F' 0x0A
'F'
'F' 0x0A