Initial Operation
Index
Subindex Data type
0x2540
0
Uint8
1
Uint16
2
Uint8
3
Uint8[246] RW Value
4
Uint8[14]
0x2600
1
Uint8[128] RW Send Cmd
2
Uint8[896] R
IF2035-PROFINET
Name
RS485 RS422 Description
String Parameter
NrOfObjects
RW Parameter ID
RW Reserved
R
Name
RS422 ASCII
Access
Cmd Answer
Read or write string parameter
Please refer to the sensor documentation for avai-
lable parameter IDs and their types
Value
Designation
RS422 commando
Buffer for a 128-character ASCII command, termi-
nation with '\n' or 0x0A
Answer from sensor without shortening, e.g., Line
feed; if buffer overflows, e.g., PRINT ALL, answer is
truncated