XG1200 User's Guide
Message
IDSeverity
S7629
CRITICAL
S7630
CRITICAL
S7631
CRITICAL
S7632
CRITICAL
S7699
CRITICAL
A.2.11

snmp (SNMP Control: 8500-8599)

Message
IDSeverity
S8500
INFO
S8501
INFO
firm-update: failed (SRAM access error).
Explanation
An error has occurred while updating firmware.
Solution
Reattempt the update process.
If the message is displayed repeatedly, note the message contents and contact your XG1200 sales
representative.
firm-update: failed (SRAM data error: invalid firmware update information).
Explanation
An error has occurred while updating firmware.
Solution
Restart the XG1200 using the "reset" command before reattempting the upate process.
If the message is displayed repeatedly, note the message contents and contact your XG1200 sales
representative.
firm-update: failed (SRAM data error: invalid boot parameter).
Explanation
An error has occurred while updating firmware.
Solution
Restart the XG1200 using the "reset" command before reattempting the upate process.
If the message is displayed repeatedly, note the message contents and contact your XG1200 sales
representative.
firm-update: failed (SRAM data error: no boot command).
Explanation
An error has occurred while updating firmware.
Solution
Restart the XG1200 using the "reset" command before reattempting the upate process.If the message is
displayed repeatedly, note the message contents and contact your XG1200 sales representative.
firm-update: failed (unknown error).
Explanation
An error has occurred while updating firmware.
Solution
Note the message contents and contact your XG1200 sales representative.
SNMP authentication failure.
Explanation
An authentication error has occurred when a connect request is being sent from an SNMP manager.
Solution
Review the setting on permission to access SNMP via a SNMP manager using the "snmp access" command.
RMON alarm by rising-threshold.
index:%1$ OID:%2$ sample:%3$ value:%4$ rising-threshold:%5$
Explanation
The current sampled value was greater than the upper threshold defined by the "RMON alarm" command, and a
trap for the corresponding RMON event was generated.
[[Inserted string]]%1$: RMON alarm index
[[Inserted string]]%2$: OID of MIB object to be monitored
[[Inserted string]]%3$: Method of determining threshold
1: An absolute value is used when determining threshold (absolute)
2: A difference between the previous and current values is used when determining threshold (delta)
[[Inserted string]]%4$: Value of MIB object to be monitored
[[Inserted string]]%5$: Upper threshold of MIB object to be monitored
All Rights Reserved, Copyright (C) PFU LIMITED 2005