Security
Handling wet loads
8.5
The lifting device is not intended for the suction of wet loads.
NOTE
Starting the combustion engine
8.6
Lift load
8.7
WARNING
WARNING
CAUTION
✓ The combustion engine has started.
✓ The minimum vacuum of -0.6 bar is established
15. Position the lifting device
above the centre of
gravity of the load.
10. carefully place the lifting device on the load.
52400043
Failure of the vacuum pump due to moisture!
Remove water from the suction surface before suctioning.
Switch on the vacuum pump after handling.
Push the manual slide valve (8) to the right
against the spring force. Allow the vacuum
pump to run dry for at least 5 minutes. Allow
the condensation to drain off.
See operating instructions for the combustion engine in the appendix.
Falling objects due to insufficient vacuum
Serious injuries or death!
Before lifting the load, ensure that the working vacuum of -
0.6 bar has been reached.
The load falls when the load securing chain is attached
Crushing hazard!
Do not reach under the load when attaching the load securing chain.
Uncontrolled rotating or swinging movements due to the load
sticking or tilting
Risk of crushing and impact!
Before lifting, ensure that the load is not stuck or tilted.
32 / 47
GB
Need help?
Do you have a question about the SH-2500-UNI-B and is the answer not in the manual?
Questions and answers