Command (PLC to controller)
Command area
Command
top channel
code
+2
2010
+3
0010
Response (Controller to PLC)
Response
area
15-12
top channel
+2
0010
+3
0000
+4
0000
+5
0000
Saving in Controller
Stores the current system data and scene group in the controller.
Command (PLC to controller)
Command area
Command
top channel
code
+2
3010
+3
0010
Response (Controller to PLC)
Response
area
15-12
top channel
+2
0011
+3
0000
+4
0000
+5
0000
Restart
Restarts the controller.
Important
When a restart command is executed, BUSY does not turn off even after the command execution bit turns off.
After a restart command is executed, perform a memory clear of BUSY on the PLC side.
FZ3 User's Manual
15-12
11-8
0010
0000
0000
0000
Bit
11-8
7-4
0000
0001
0000
0001
0000
0000
0000
0000
15-12
11-8
0011
0000
0000
0000
Bit
11-8
7-4
0000
0001
0000
0001
0000
0000
0000
0000
Communicating through Serial Communication (PLC Link)
Bit
7-4
3-0
0001
0000
0001
0000
3-0
0000
Command code
0000
Store response target command codes.
0000
Response code
Command execution result
OK: 0 (0000 0000)
0000
NG: -1 (FFFF FFFF)
Bit
7-4
3-0
0001
0000
0001
0000
3-0
0000
Command code
0000
Store response target command codes.
0000
Response code
Command execution result
OK: 0 (0000 0000)
0000
NG: -1 (FFFF FFFF)
Description
Set command
codes.
Description
Description
Set command
codes.
Description
165