Output polarity
Output control
7
Output period
Gate ON delay
Output time
Timeout
Number of delay
One-shot OR signal
212
Controlling/Outputting through Parallel Communication
Setting
value
Item
[Factory
default]
[On at
NG]
On at
OK
[None]
Handshaking
Synchronization
output
2.0 to
5000.0 ms
[10.0 ms]
1.0 to
1000.0 ms
[1.0 ms]
1.0 to
1000.0 ms
[5.0 ms]
0.5 to 120.0
s
[10.0 s]
1 to 15
[1]
ON
[OFF]
0.1 to
Output time
1000.0 ms
[5.0 ms]
Description
Select whether to turn on OR and DO0 to 15 when
judgement result is OK or when it is NG.
Method to output measurement results without synchronizing
with external devices.
Reference: When "Output Control" Is Set to "None" (p.218)
Method to output measurement results while synchronizing with
external devices.
Reference: When "Output Control" Is Set to "Handshaking" (p.220)
Method to output measurement results while
synchronizing with line processing timing. The STEP
signal is ignored the number of times set in "Number of
delay", and measurement results are output when the
STEP signal next turns on. If through images are
displayed, however, synchronization output cannot be
used.
Reference:
When "Output Control" Is Set to
"Synchronization Output" (p.221)
Valid only when "Output control" is set to "None".
Set the cycle by which measurement results are output.
Set the cycle so that the interval is equal to or longer
than "Gate ON delay + Output time" and shorter than
measurement interval.
If the cycle is longer than the measurement interval,
output timing will be delayed while measurement is
being repeated.
Set the time from when results are output to the parallel
interface to when the GATE signal turns on. Waiting
time until data output is stable.
Set this so that it is longer than the external device
delay time.
Valid only when "Output control" is set to "None" or
"Synchronization output".
Set the GATE signal ON time. Set the time required for
external devices to acquire measurement results.
Valid only when "Output control" is set to
"Handshaking".
A timeout error occurs when no response from external
devices is received within the time that has been set.
Valid only when "Output control" is set to
"Synchronization output".
Set the number of times that the STEP signal turning
on will be ignored before measurement results of the
STEP signal are output.
Select whether to maintain OR signal output for an
arbitrary amount of time.
Set the OR signal output time.
Valid only when "One-shot OR signal" is set to ON. Set
a value that is shorter than the measurement time.
FZ3 User's Manual