Omron FZ3 User Manual page 42

Vision sensor xpectia fz3 series
Hide thumbs Also See for FZ3:
Table of Contents

Advertisement

The screen returns to the RUN window.
1
Important
When [Transfer data] is executed, the results of [Trend Monitor] and [Expression], etc. are cleared.
If the scene or scene group was switched or any setting of a processing unit was changed during operation
using an external command, the result is not yet reflected when you switch to the non-stop adjustment window.
If non-stop adjustment is performed after changing the scene group during operation, scene group data may be
overwritten against your wish.
Measurement commands (parallel, non-procedure, PLC link) and continuous measurement commands (parallel
only) are the only communication commands that are accepted during data transfer.
Data transfer takes a longer time when the scene group file size is larger.
If the RUN window is displayed in the fast view mode, non-stop adjustment cannot be performed.
Communication settings cannot be changed on the non-stop adjustment window.
Do not register any new camera image input unit on the non-stop adjustment window.
If RAMDisk does not have enough free disk capacity, data may not be transferred. Specify an image logging
destination other than RAMDisk or otherwise set applicable items to minimize the usage of RAMDisk.
Performing non-stop adjustment changes the display mode to freeze.
If image logging is performed in the non-stop adjustment mode, data transfer may be disabled. To prevent this
from happening, set the trigger interval longer than the logging time.
40
Setting Operation Mode
FZ3 User's Manual