6-9 Advanced Settings (Connection, Communication Cycle Time, Slave Function
Note
Communication cycle time refers to the required time of remote I/O communications
between the master and a slave. Communication cycle time settings properly made will
prevent the fluctuation of the time of remote I/O communications with the slave.
Furthermore, by setting the communication cycle time to a larger value, the prolonged
processing operation of the slave will not be treated as a communications error. If the
actual remote I/O communications time is shorter than the set communication cycle
time, the remote I/O communications will keep pace with the communication cycle
time. If actual I/O communications take longer than the set communication cycle time,
the I/O communications will be continued regardless of the set communication cycle
time.
6-9-3

Setting Message Timers

Component - Parameter - Edit - Message Timer Tab
Note: This procedure is supported by the CS1W-DRM21(-V1) and CJ1W-DRM21 only.
A message timer is by default set to 2 s (2000 ms). They can be set 1-ms increments
to between 500 and 30,000 ms.
To change a message timer value, use the following procedure.
1. Double-click the node address (#) or select the node address and click the Edit
Button. The following dialog box will be displayed.
2. Set the value and click the OK Button.
Note To set the same value for all the devices, select the node addresses and click the
Copy to All Device Button.
Settings, Etc.)
6-9-3
Setting Message Timers
6-39