Setting and Resetting Inputs

3-8

Setting and Resetting Inputs

Precaution
1,2,3...
Note The following table shows the inputs that can be set or reset.
This section describes how to set (turn ON) and reset (turn OFF) the
ZEN bits from the ZEN Support Software.
The ZEN must be connected and online and the project file opened
before inputs can be set or reset. Also, the ZEN and the ZEN Support
Software programs must be the same before inputs can be set or
reset. Use the procedures outlined under 3-3 Transferring Programs
to the ZEN (page 45), 3-4 Transferring Programs from the ZEN
(page 46), and 3-5 Verifying Programs with the ZEN (page 47) to
transfer and verify the programs.
Confirm safety before turning relays ON or OFF.
Use the procedure outlined under 3-6 Operating and Stopping the
1.
ZEN to start ZEN operation. Check that the Status Bar display
changes from STOP to RUN.
Use the procedure outlined under 3-7 Monitoring Programs to
2.
change to MONITOR mode.
3.
Use the mouse or cursor keys to move to the input that is to be
set or reset, and then perform either of the following operations:
• Select ZEN(Z)/Set/Reset Operation and then either Set
Operation(W) or Reset Operation(F) from the Menu Bar.
• Right-click and then select Set/Reset Operation and then
either Set Operation(W) or Reset Operation(F).
Bit type
CPU Unit input bits (I)
CPU Unit output bits (Q)
Expansion I/O Unit input
bits (X)
Expansion I/O Unit output
bits (Y)
Work bits (M)
Holding bits (H)
Comments
Input terminal ON/OFF status has priority.
Set/reset possible for inputs only. (Not
possible for outputs.)
Input terminal ON/OFF status has priority.
Set/reset possible for inputs only. (Not
possible for outputs.)
Section 3-8