PLC Setup
Acceleration Rate (Pulse Output 0 Origin Return Acceleration Rate)
Programming
Settings
Console
address
Word
Bits
+272
00 to 15 Pre-Ver. 2.0 CPU
Units: 0001 to
07D0 hex
CPU Units Ver.
2.0: 0001 to FFFF
hex
(See note.)
Deceleration Rate (Pulse Output 0 Origin Return Deceleration Rate)
Programming
Settings
Console
address
Word
Bits
+273
00 to 15 Pre-Ver. 2.0 CPU
Units: 0001 to
07D0 hex
CPU Units Ver.
2.0: 0001 to FFFF
hex
(See note.)
Pulse Output 1 Settings
330
Default
0000
Sets the origin search acceleration
hex
rate for pulse output 0.
Pre-Ver. 2.0 CPU Units:
1 to 2,000 pulses/4 ms
CPU Units Ver. 2.0:
1 to 65,535 pulses/4 ms
Note When the CX-Programmer is being used to make the setting, the setting is
input in decimal.
Default
0000
Sets the origin search deceleration
hex
rate for pulse output 0.
Pre-Ver. 2.0 CPU Units:
1 to 2,000 pulses/4 ms
CPU Units Ver. 2.0:
1 to 65,535 pulses/4 ms
Note When the CX-Programmer is being used to make the setting, the setting is
input in decimal.
Note CX-Programmer Tabs
CX-Programmer Ver. 3.1 or lower: Define Origin Operation Settings Field of
Define Origin 2
CX-Programmer Ver. 3.2 or higher: Pulse Output 1
Function
Area flags/
---
Function
Area flags/
---
Section 7-1
Related
Time when
Auxiliary
setting is read
by CPU Unit
bits
When operation
starts
Related
Time when
Auxiliary
setting is read
by CPU Unit
bits
When operation
starts