Omron CJ - 08-2008 Operation Manual page 213

Programmable controllers
Table of Contents

Advertisement

Programming Devices
CX-Programmer Connecting Cables
USB
Con-
Connec-
Cable model
necting
tor
Cable
Model
CS1W-
D-sub, 9-
CS1W-CN226/626
CIF31
pin
(length: 2 m/6 m)
female
CQM1-CIF02
(length: 3.3 m)
XW2Z-200S-V/
500S-V (length: 2 m/
5 m)
XW2Z-200S-V/
500S-V (length: 2 m/
5 m)
XW2Z-200S-CV/
500S-CV (length:
2 m/5 m)
XW2Z-200S-V/
500S-V (length: 2 m/
5 m)
USB
Con-
Connec-
Cable model
necting
tor
Cable
Model
CS1W-
D-sub, 9-
XW2Z-200S-CV/
CIF31
pin
500S-CV (length:
female
2 m/5 m)
CS1W-
D-sub, 9-
XW2Z-200S-V/
CIF31
pin
500S-V (length: 2 m/
female
5 m)
Cables Connecting to CPU Units
Cable 1
Connec-
Connec-
tor
CS/CJ-
Not required.
series
periph-
eral
C-series
C-series
periph-
periph-
eral
eral
D-sub, 9-
D-sub, 9-
pin male
pin
female
D-sub, 9-
D-sub, 9-
pin male
pin
female
RS-232C
Not required.
D-sub, 9-
pin male
RS-232C
Not required.
D-sub, 9-
pin male
Cables Connecting to Serial Communications Boards/Units
Cable 1
Connec-
tor
RS-232C
Not required.
D-sub, 9-
pin male
RS-232C
Not required.
D-sub, 9-
pin male
Note The CX-Programmer can be used for remote programming and monitoring. It
can be used to program and monitor not only the PLC to which it is directly
connected, but also to program and monitor any PLC connected through a
Controller Link or Ethernet network to which the PLC that the CX-Programmer
is connected to is a part of. All programming and monitoring functionality for
the directly connected PLC is supported for remote programming and moni-
toring, the PLC can be connected though either the peripheral or an RS-232C
port, and either the peripheral bus or Host Link bus can be used. Remote pro-
gramming is possible for up to three levels of networks (counting the local net-
work but not counting the peripheral bus or Host Link connection between the
CX-Programmer and the local PLC).
Cable 2
Cable model
tor
CS1W-CN114
(length: 5 cm)
CS1W-CN118
(length: 0.1 m)
CS1W-CN118
(length: 0.1 m)
Cable 2
Section 3-3
Unit port
communications
Connec-
tor
(network)
CS/CJ-
Peripheral Bus
series
(Toolbus) or Host
periph-
Link (SYSWAY)
eral
CS/CJ-
Host Link
series
(SYSWAY)
periph-
eral
CS/CJ-
Peripheral Bus
series
(Toolbus) or Host
periph-
Link (SYSWAY)
eral
CS/CJ-
Host Link
series
(SYSWAY)
periph-
eral
RS-232C
Peripheral Bus
D-sub, 9-
(Toolbus) or Host
pin
Link (SYSWAY)
female
Host Link
(SYSWAY)
Unit port
communications
(network)
RS-232C
Host Link
D-sub, 9-
(SYSWAY)
pin
female
Serial
mode
Serial
mode
165

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents