CJ1-H-R, CJ1-H, CJ1M, and CJ1 CPU Unit Comparison
Item
I/O tables
Detailed information on
I/O table creation errors
Displaying presence of
first rack word setting
on Programming Con-
sole
Built-in I/O
Serial PLC Link
Scheduled interrupts set in incre-
ments of 0.1 ms
Battery
Opera-
CPU Unit startup
tion when
Unit
doesn't
complete
startup
process
Sequence
Differentiated LD NOT,
instruc-
AND NOT, and OR NOT
tions
instructions
OUTB, SETB, and
RSTB instructions to
manipulate individual
bits in DM and EM Area
words
Timer/
TIMU (0.1-ms, BCD),
counter
TIMUX (0.1-ms, binary),
instruc-
TMUH (0.01-ms, BCD),
tions
TMUHX (0.01-ms,
binary)
Format for updating
PVs for TIM, TIMH,
TMHH, TTIM, TIML,
MTIM, CNT, CNTR,
CNR, TIMW, TMHW,
CNTW instructions
Special
32-bit signed data line
math
coordinates and X axis
instruc-
starting point specifica-
tions
tion for APR instruction
Floating-
High-speed trigonomet-
point deci-
ric functions: SINQ,
mal
COSQ, and TANQ
instruc-
instructions
tions
Single-precision calcu-
lations and conversions
Conversions between
single-precision float-
ing point and ASCII
Double-precision calcu-
lations and conversions
Text
Text string and table
string,
data processing instruc-
table
tion execution
data, and
data shift
Stack insertions/dele-
instruc-
tions/replacements and
tions
stack counts with table
processing instructions
56
CJ1-H-R CPU
Unit
CJ1H-CPU6@H-R
CJ1H-CPU6@H
Detailed I/O table error information is stored in A261 whenever the I/O tables
cannot be created for any reason.
It's possible to confirm if the first rack word has been specified for the system on
the Programming Console display.
The first rack word is specified from the CX-Programmer, making it previously
impossible to confirm the setting from the Programming Console.
Not supported.
Not supported.
Supported.
Not supported.
CPM2A-BAT01
Starting or not starting (standby) the CPU Unit in MONITOR or RUN mode even
if a Unit has not completed startup processing can be specified in the PLC
Setup.
Supported.
Supported.
Supported.
Not supported.
Either BCD or
binary can be
selected (with CX-
Programmer Ver.
7.1 or higher).
Supported.
Either BCD or binary can be selected (with CX-Programmer Ver. 3.0 or higher).
Supported.
Supported (with
Not supported.
CX-Programmer
Ver. 7.1 or higher).
Supported (enabling standard deviation calculations).
Supported.
Floating point can be converted to ASCII for display on PTs.
ASCII text strings from measurement devices can be converted to floating-point
decimal for use in calculations.
Supported (enabling high-precision positioning).
Data processing can be performed normally or in the background (specified for
each instruction).
(Using time slices to process instruction over several cycles reduces the effect
of these instructions on the cycle time.).
Supported.
Effective for tracking workpieces on conveyor lines.
CJ1-H CPU Unit
CJ1G-CPU4@H
CJ1M-CPU2@/1@
CJ1M-CPU2@
Supported.
Supported.
CJ1W-BAT01
Section 1-7
CJ1M CPU Unit
CJ1 CPU Unit
CJ1G-CPU4@
Not supported.
Not supported.
Not supported.
Not supported.
Not supported.
CPM2A-BAT01
CPU Unit
standby (fixed)
Not supported.
(The same
results can be
achieved by
combining differ-
entiated LD,
AND, and OR
instructions with
the NOT instruc-
tion.)
Not supported.
BCD only
Not supported.
Not supported.
Not supported.
Not supported.
Normal process-
ing only.
Not supported.