Omron CJ - PROGRAMMING MANUAL 08-2008 Programming Manual page 428

Programmable controllers
Hide thumbs Also See for CJ - PROGRAMMING MANUAL 08-2008:
Table of Contents

Advertisement

PLC Comparison Charts
Item
File Mem-
READ DATA
ory
FILE/WRITE
Instruc-
DATA FILE
tions
WRITE TEXT
FILE
READ PRO-
GRAM FILE
CHANGE STEP
PROGRAM
Display
DISPLAY MES-
Instruc-
SAGE
tions
DISPLAY LONG
MESSAGE
I/O DISPLAY
TERMINAL
MODE
Clock
CALENDAR ADD CADD
Instruc-
CALENDAR
tions
SUBTRACT
HOURS TO SEC-
ONDS
SECONDS TO
HOURS
CLOCK
ADJUSTMENT
Debug-
TRACE MEM-
ging
ORY SAMPLING
Instruc-
MARK TRACE
tions
Failure
FAILURE
Diagno-
ALARM/SEVERE
sis
FAILURE ALARM
Instruc-
tions
FAILURE POINT
DETECTION
390
Mne-
CJ1-H/CJ1M Series
monic
CJ1-H-R
CJ1-H
FREAD/
Yes
FWRIT
TWRIT
Yes (*6)
FILP
No
FLSP
No
MSG
Yes (Messages ended by NUL)
LMSG
No
IODP
No
TERM
No
Yes
CSUB
Yes
SEC
Yes
HMS
Yes
DATE
Yes
TRSM
Yes
MARK
No
FAL/
Yes (Messages ended by NUL, text strings
FALS
stored in order of leftmost to rightmost byte
and then rightmost to leftmost word. FAL
number specified in binary.)
FPD
Yes (Messages ended by NUL, text strings
stored in order of leftmost to rightmost byte
and then rightmost to leftmost word. FAL
number specified in binary.)
CS1-H
C200HX/HG/
Series
HE
CJ1-M
No
No
No
No
Yes (Messages ended by CR)
Yes (Mes-
sages ended
by CR)
No
Yes
No
No
Yes
Yes
No
Yes
No
Yes (Mes-
sages ended
by CR, text
strings stored
in order of left-
most to right-
most byte and
then right-
most to left-
most word.
FAL number
specified in
BCD.)
Yes (Mes-
sages ended
by CR, text
strings stored
in order of left-
most to right-
most byte and
then right-
most to left-
most word.
FAL number
specified in
BCD.)
Appendix A
CVM1/CV
CQM1H
Series
Yes (FILR/
No
FILW)
No
No
Yes
No
Yes
No
No
No
Yes
No
No
No
Yes
No
Yes
No
Yes
Yes
Yes
Yes
Yes (*1)
No
Yes
Yes
Yes (Mark
No
number speci-
fied in BCD)
Yes (Mes-
Yes (Mes-
sages ended
sages ended
by CR, text
by CR, text
strings stored
strings stored
in order of left-
in order of left-
most to right-
most to right-
most byte and
most byte and
then right-
then right-
most to left-
most to left-
most word.
most word.
FAL number
FAL number
specified in
specified in
BCD.)
BCD.)
Yes (Mes-
Yes (Mes-
sages ended
sages ended
by CR, text
by CR, text
strings stored
strings stored
in order of left-
in order of left-
most to right-
most to right-
most byte and
most byte and
then right-
then right-
most to left-
most to left-
most word.
most word.
FAL number
FAL number
specified in
specified in
BCD.) (*1)
BCD.)

Advertisement

Table of Contents
loading

Table of Contents