Omron CJ - PROGRAMMING MANUAL 08-2008 Programming Manual page 410

Programmable controllers
Hide thumbs Also See for CJ - PROGRAMMING MANUAL 08-2008:
Table of Contents

Advertisement

PLC Comparison Charts
Item
Initial
I/O
Input response time
set-
for Basic I/O Unit
tings
Rack first addresses Set in I/O table from Programming Device (but
First address of
SYSMAC BUS Opti-
cal I/O Units by Mas-
ter
Operation for I/O
verification error
Memory User memory pro-
tection
Holding areas
Holding I/O words
for fatal errors
(except power fail-
ure)
Memory saved using
IOM Hold Bit when
power to PLC is
turned ON
Memory saved using
Forced Status Hold
Bit when power to
PLC is turned ON
DIP switch status
monitoring
Instruc-
Setting indirect DM
tions
data to BCD or
binary
Multiple use of
JMP(0) instruction
Operation for
instruction errors
(Continue or stop)
Background execu-
tion
File
Automatic transfer at
memory
startup
EM file memory
Inter-
Interrupt response
rupts
Error detection
Holding I/O inter-
rupts during I/O
interrupt program
execution
Power OFF interrupt
enabled/disabled
Scheduled interrupt
interval setting
372
CJ1-H/CJ1M Series
CJ1-H-R
CJ1-H
CJ1-M
Set in PLC Setup
order of rack numbers is fixed).
No
No
Set on DIP switch
No
No
Set in PLC Setup
Set in PLC Setup
Yes
Direct input possible
Multiple use already possible
Set in PLC Setup
Yes
Determined by DIP switch setting (Automati-
cally read from Memory Card)
Set in PLC Setup
No
Set in PLC Setup
No
Set in PLC Setup
Set in
Set in
Set in
PLC
PLC
PLC
Setup
Setup
Setup
(10 ms,
(10 ms,
(10 ms,
1.0 ms,
1.0 ms)
1.0 ms,
0.1 ms)
0.1 ms)
CS1-H Series
C200HX/HG/
HE
No
No
No
No
Set on DIP
switch
No
No
Set in PLC
Setup
Set in PLC
Setup
Yes
No
No
No
No
Determined
by DIP switch
setting (Auto-
matically read
from memory
cassette)
No
Set in PLC
Setup
(C200H/High-
speed
response)
Set in PLC
Setup
No
No
Set in PLC
Set in PLC
Setup
Setup (10 ms,
1 ms, 0.1 ms)
(10 ms,
1.0 ms)
Appendix A
CVM1/CV
CQM1H
Series
No
Set in PLC
Setup
Set in PLC
No
Setup (Rack
No. order can
be set.)
Set in PLC
No
Setup
Set in PLC
No
Setup
Determined
Set on DIP
by key switch
switch
setting
Set in PLC
No
Setup
Set in PLC
No
Setup
Set in PLC
Set in PLC
Setup
Setup
Set in PLC
Set in PLC
Setup
Setup
No
Yes
Set in PLC
No
Setup
Set in PLC
No
Setup
No
No
No
No
Set in PLC
Determined
Setup or DIP
by DIP switch
switch setting
setting (Auto-
(Automati-
matically read
cally read
from Memory
from Memory
Card)
Card)
No
No
No
No
No
No
Set in PLC
No
Setup
Set in PLC
No
Setup
Set in PLC
No
Setup (10 ms,
1 ms, 0.5 ms)