PLC Comparison Charts
Item
Initial
Power
Restart Continua-
set-
supply
tion Bit Hold
tings
Startup mode
(contd.)
Startup Condition
Settings
Startup trace
Detect low battery
voltage
Momentary power
interruption time
Power OFF detec-
tion delay time
Momentary power
interruption as fatal/
non-fatal error
Cycles
I/O refresh
Constant cycle time
Monitor cycle time
Detect cycle time
over disable
Asynchronous
instruction execu-
tion and peripheral
servicing
CPU
Parallel processing
pro-
modes
cessing
Peripheral Servicing
mode
Priority Mode
Serial
RS-232C port com-
commu-
munications settings
nica-
Peripheral port com-
tions
munications settings
Communications
Board communica-
tions settings
Servic-
Service time
ing
other
periph-
erals
Measure CPU Bus
Unit service interval
Stop Special I/O Unit
Cyclic Refreshing
CPU Bus link
application
CJ1-H/CJ1M Series
CJ1-H-R
CJ1-H
CJ1-M
No
Set in PLC Setup
Yes
No
Set in PLC Setup
No
Set in PLC Setup
No
No
Set in PLC Setup (1 to 32,000 ms)
Set in PLC Setup (10 to 40,000 ms) (Initial set-
ting: 1,000 ms fixed)
No
No
Yes
Yes
No
Yes
DIP switch setting for auto-detect or PLC
Setup
Set in PLC Setup
No
Set in PLC Setup
(Fixed Peripheral Servicing Time)
No
Set in PLC Setup
No
CS1-H Series
C200HX/HG/
HE
No
Set in PLC
Setup
No
No
Set in PLC
Setup
No
Set in PLC
Setup
(Time that
operation will
continue after
power OFF
has been
detected)
No
Set in PLC
Setup (Spe-
cial I/O Units
only)
Set in PLC
Setup(1 to
9,999 ms)
Set in PLC
Setup (0 to
99) Unit: 1 s,
10 ms,
100 ms (Ini-
tial setting:
120 ms fixed)
Set in PLC
Setup
No
Yes
No
No
DIP switch setting selects defaults or PLC
Setup
PLC Setup
PLC Setup
Set in PLC
Setup
(Built-in RS-
232C port,
Communica-
tions Board,
peripheral
port)
No
Set in PLC
Setup
No
Appendix A
CVM1/CV
CQM1H
Series
Set in PLC
No
Setup
Set in PLC
Set in PLC
Setup
Setup
No
No
Set in PLC
No
Setup
Set in PLC
Set in PLC
Setup
Setup
Set in PLC
No
Setup
No
No
Set in PLC
No
Setup
Set in PLC
No
Setup
Set in PLC
Set in PLC
Setup (1 to
Setup(1 to
32,000 ms)
9,999 ms)
Set in PLC
Set in PLC
Setup (10 to
Setup (0 to
40,000 ms)
99) Unit: 1 s,
(Initial set-
10 ms,
ting: 1,000 ms
100 ms (Ini-
fixed)
tial setting:
120 ms fixed)
No
Set in PLC
Setup
Set in PLC
No
Setup
No
No
No
No
Set on DIP
Set in PLC
switch.
Setup
No
PLC Setup
No
Set in PLC
Setup
(Built-in RS-
232C port,
Communica-
tions Board,
peripheral
port)
Set in PLC
No
Setup
No
No
Set in PLC
No
Setup
373