Changing the Timer/Counter PV Refresh Mode
BCD Mode/ Binary Mode Confirmation
314
Select this check box to enable the setting.
2. Click the General Tab, and select Execute Timers/Counters as Binary.
• Not selected (default): BCD mode
• Selected: Binary mode
The timer/counter PV refresh mode set value set under the PLC properties
will be stored in the CPU Unit's user memory when the user program is
transferred from the CX-Programmer to the CPU Unit.
When the setting is changed, the following dialog box will be displayed au-
tomatically.
Click the OK Button to execute the program check. The program check results
will be displayed in the output window.
Example: The TIM instruction has been used even though the mode has been
changed to binary mode.
The program check results are displayed in the output window.
Example: The timer/counter operation mode is different, so TIM
cannot be used.
A09915 in the Auxiliary Area (Timer/Counter PV Refresh Mode Flag) can be
used to check whether a CPU Unit is operating in BCD mode or binary mode.
Name
Timer/Counter PV
Refresh Mode Flag
Cancel
Address
A09915
0: BCD mode
1: Binary mode
Section 6-4
TIM is displayed in
red.