Cover - IBM Application System/400 Service Information

Table of Contents

Advertisement

4
Disconnect the battery cable from the
holder.
5
CAUTION:
The battery is an alkaline battery. Do
not burn or charge the battery. Discard
the battery as instructed by local regu-
lations.
(RSFTC229)
Pull the batteries out from the holder and
exchange the batteries.
4-6
AS/4009401 Service Information
It is recommended that all three batteries
be exchanged every 18 months.
6
Install the control panel batteries by
reversing the removal procedure.
Note: Be careful to observe polarity when
installing batteries.
This ends the procedure.
Cover
1
Power off the system. (See "Powering Off
and Powering On the System" on
page 5-2.)
2
Disconnect the power cord from the elec-
trical outlet.
3
Disconnect all cables attached to the 9401
including the power cord.
4
Perform the following:
a. Press on the two tabs as shown.
b. Pull the bezel toward you from the top.
c. Lift to remove the bezel from the
chassis.

Advertisement

Table of Contents
loading

Table of Contents