IBM Application System/400 Service Information page 134

Table of Contents

Advertisement

fl.
RV2N514-0
4
Disconnect the signal and power cables
from the end of the disk unit.
fl.
RV2N515-1
5
Pivot the disk unit away from the chassis
and pull it out.
4-8
AS/400 9401 Service Information
fl.
RV2N516-1
6
Warning: The disk drive and logic card
are sensitive to electrostatic discharge_
(See Appendix A, "Working with
Electrostatic Discharge-Sensitive Parts" on
page A-1_)
Warning: Do not hold or apply pressure to
the disk enclosure cover. This can cause
the disk enclosure cover to touch and
damage the disks inside.
Place the disk unit with the disk tray up.
Remove the screws that hold the disk tray
to the disk unit.
7
Move the address jumper from the original
disk unit to the new disk unit.
Note: The address jumper on a 6104 disk
unit is located on the same end as the
signal and power connectors. The address
jumpers on a 6601 disk unit are located on
the opposite end from the signal and power
connectors.