IBM Application System/400 Service Information page 86

Table of Contents

Advertisement

Action
If only a type number is listed, go to the "Type and Part
Failing Item
Number Lisf' on page 2-62 to determine the part number.
Code
Description
FI02096
I/O processor attached to the load-source
Exchange the following:
device
• OOOO-Chassis
FI02097
Load-source device and SCSI interface
1. Select Function 01 (Display Selected IPL) on the control
panel to display the existing IPL mode.
2. If the mode is A or B, disk unit 1 is the failing item.
Exchange the following:
• 6104-disk unit
• 6601--disk unit
3. If the IPL mode is D, the tape unit is the failing item.
Exchange the following:
• 6343-Extemal 1/4-inch tape unit.
• 0001-External 1/4-inch tape unit cable.
4. For SCSI cable use:
• OOOO-Chassis
FI02098
Load-source device
1. Select Function 01 (Display Selected IPL) on the control
panel to display the existing IPL mode.
2. If the mode is A or B, disk unit 1 is the failing item.
Exchange the following:
• 6104-disk unit
• 6601--disk unit
3. If the IPL mode is D, the tape unit is the failing item.
Exchange the following:
• 6343-External 1/4-inch tape unit.
• 0001-External 1I4-inch tape unit cable.
FI02105
See FI011 05.
FI02106
See FI011 06.
FI02107
See F101107.
FI02111
See F101111.
FI02112
See F101112.
FI02114
See F101114.
FI02202
SCSI/OP panel cable
Exchange the following:
• 0001-External 1/4-inch tape unit cable.
• OOOO-Chassis
FI02203
Power supply and cables
Exchange the following:
• OOOO-Chassis
F102204
Any device or part connected to the
Exchange the following:
system power distribution may be the
• 6152-1-line EIA-232N.24 Communications Adapter
failing item.
• OOOO-Chassis
• 6104-disk unit
• 6601--disk unit
2-60
AS/400 9401 Service Information

Advertisement

Table of Contents
loading