IBM Application System/400 Service Information page 111

Table of Contents

Advertisement

b. Select IPL type D, mode M (see
"Selecting IPL and Mode" on
page 5-2).
c. Select Function 03 (Start IPL) on the
control panel and press Enter to
perform an IPL.
Does a display appear?
No
Yes
~
This ends the procedure.
5
Exchange the chassis (see "Chassis" on
page 4-2).
This ends the procedure.
6
Copy the main storage dump from the disk
unit to the tape unit (see "Copying Main
Storage Dump to Tape or Diskette" in the
Service Functions User's Guide).
7
Report a Licensed Internal Code problem
to your next level of support.
This ends the procedure.
VLlC-PIP4
Dedicated service tools (DST) or a service func-
tion under DST ended abnormally. DST was in
the disconnected status or lost touch with the
initial program load (IPL) console because of a
console failure and could not communicate with
the user.
1
Select Function 21 (Bring up DST) and
press Enter on the control panel to start
DST again (see "Selecting IPL and Mode"
on page 5-2).
Does the DST Sign On display appear?
Yes
No
~
Go to step 3 of this procedure.
2
Perform the following (see "System Tools"
in the Service Functions User's Guide):
a. Select the Start a service tool option.
b. Select the Vertical Licensed Internal
Code log option.
c. Copy the contents of the Vertical
Licensed Internal Code log to tape (see
"Copy the Contents of VUC Log" on
page 5-13).
d. Return to this procedure and continue
with step 3 of this procedure.
3
Perform a main storage dump (see
"Perform a Main Storage Dump to Disk" in
the Service Functions User's Guide).
4
Copy the main storage dump (see "Copying
Main Storage Dump to Tape or Diskette" in
the Service Functions User's Guide).
5
Report a Licensed Internal Code problem
to your next level of support.
This ends the procedure.
VLIC-PIP7
The system detected a Licensed Internal Code or
hardware problem associated with a specific 1/0
processor card, or with bus hardware.
This failure might only occur when a specific set of
conditions is present.
1
Has an IPL been done after the failure
occurred?
No
Yes
Go to step 3 of this procedure.
2
Perform the following:
a. Select IPL type A, mode M (see
"Selecting IPL and Mode" on
page 5-2).
b. Select Function 03 (Start IPL) and
press Enter on the control panel to
perform an IPL.
3
Does the same system reference code
(SRC) occur on the control panel, appear
on a display, or appear in the error log?
No
Yes
~
Go to step 7 of this procedure.
Chapter 3. Problem Isolation Procedures
3-21