IBM Application System/400 Service Information page 24

Table of Contents

Advertisement

Yes
No
Select the IPL using the type
that the system is currently set
at (A, B, or D) and mode N
(see "Selecting IPL and Mode"
on page 5-2).
Check to determine if the IPL
can complete successfully from
a remote location. If not, con-
tinue with the next step of this
procedure.
4
Verify that the cable connecting the modem
to the communications adapter card in the
chassis is fastened correctly.
5
Perform the following:
a. Dial the telephone number for the
system.
b. Wait at least 40 seconds for the system
to answer.
Note: The Ring Indicator signal is used to
start the remote IPL. If the caller hangs up
the telephone before the system discon-
nects the line (indicated by the return of the
dial tone), the IPL will not complete. The
caller may hear other tones before the dial
tone.
Was the telephone answered in 40
seconds?
Yes
No
Go to step 7 of this procedure.
6
Does the IPL complete successfully?
No
Yes
This ends the procedure.
7
The IPL from a remote location was not
successful. The following steps show you
how to start a manual IPL and how to
analyze the remote IPL problem.
Select the IPL using the type that the
system is currently set at (A, B, or D) and
mode M (manual), see "Selecting IPL and
Mode" on page 5-2.
1-12
AS/400
9401 Service Information
8
Start an IPL by powering on the system
(see "Powering Off and Powering On the
System" on page 5-2).
Does the IPL complete successfully?
Yes
No
9
Enter
If there is a reference code, go
to "Unit Reference Code
Tables" on page 2-3.
If there is no reference code,
exchange the chassis. See
''Type and Part Number Lisf' on
page 2-62 to determine the
part and see "Chassis" on
page 4-2 for the procedure.
This ends the procedure.
DSPSYSVAL QRMTIPL
(the Display System Value command) on
the command line.
Does the operating system have the correct
value of 1 for the remote power-on func-
tion?
Display System Value
5Y'tem: 59990009
System value • • • • • • • • • : QRMTIPL
Description
• • . . • • • . • : Remote power on and IPl
Initial value
. . . • • • • • : 1
9: Not allowed
1- Allowed
Figure
1-6. Example of Remote Power-on Configura-
tion Display for QRMTIPL
Yes
No
Perform the following:
a. Change the value to 1 by
entering
CHGSYSVAL SYSVAL(QIPLRMT) VALUE('l')
(the Change System Value
command) on the command
line.
Note: If you cannot change
this value, contact the customer
for authorization.
b. Power off the system by
entering
PWRDWNSYS * IMMED

Advertisement