Accept Missing Disk Units; Assign Missing Load-Source Disk - IBM Application System/400 Service Information

Table of Contents

Advertisement

data. The Type field indicates that the machine
type reported by the disk unit was not identified by
the system. The Model field indicates any four
numbers.
Oisplay Missing Disk Units
The following disk units have incorrect vital product datll:
Serial
ASP
Unit Type
Model
NLmlber
Address
Status
_1 __ 2_
10-12345_
0920-8U1ElFFFF
Active_
More •••
Press Enter to use Dedicated Service Tools (OST).
Figure 3-15. Display Missing Disk Units (VPD Not
Correct)
Display Missing Disk Units (Configura-
tion Change Not Complete):
If you see
the display shown in Figure 3-16, a system disk
configuration change cannot be completed
because the disk units shown are missing or sus-
pended. Correct the problem using the reference
codes. If the reference code is 0000, or if the
problem is corrected, use the Suspend/resume
mirrored protection option on the Work with Disk
Unit Recovery display under Work with Disk Units
to enable mirrored protection. If you were per-
forming the system disk configuration, perform the
configuration again.
Display Missing Disk Units
A system configuration change that is not complete ClInnot
be completed.
Disk units required to complete the
configuration change are missing or suspended. The following
disk units are missing or suspended:
Serial
ASP
Unit
Type
Model
Number
Address
Reference Code
_1_ _Z_
619Z
0015
19-IZ345_
S9W-SZaeFFFF
9999
Press Enter to use Dedicated Service Tools eDST).
Fll:Display unit status
More •••
Figure 3-16. Display Missing Disk Units Display (Con-
figuration Change Not Complete)
3-34
AS/400 9401 Service Information
Accept Missing Disk Units:
If you see the
display shown in Figure 3-17, an error caused the
system to suspend mirrored protection on the disk
units shown. You may continue the IPL with sus-
pended units or use the reference codes to correct
the problem. If you correct the problem, you must
enable mirrored protection on the disk units shown
after you repair them. Use the Suspend/Resume
Mirrored Protection option on the Work with Disk
Unit Recovery display under Work with Disk Units
to enable mirrored protection.
Accept MisSing Disk Units
The follOWing disk units are part of a mirrored pair Ilnd were
suspended by the system due to an error:
Serial
ASP Unit Type Model
Number
Address
Reference Code
_1_ _Z_
610Z
9015
19-1Z345_
0199-Q2QOFFFF
19ZE
Press Enter to continue the IPl.
F6"'Use Dedicated Service Tools (DST)
Fll=Display unit status
Figure 3-17. Accept Missing Disk Units
More •••
Assign Missing Load-Source Disk:
If
you see the display shown in Figure 3-18 on
page 3-35, one of the two mirrored load-source
disk units is missing, and the system can identify
the device as an non-configured disk unit. The
disk unit displayed matches the missing device by
type, model, and serial number. You may press
the Enter key to assign the displayed device as
the other load-source mirrored disk device.