3.3.4. Transformer connection. Configuring the machine voltage
HS-6013/HS-6017 models
Disconnect and mechanically lock the external automatic switch.
•
Remove the support cover (A) from the junction box located on the rear panel (Fig. 3.8).
•
Connect the voltage selector (B) onto the transformer connector (C) in accordance with the power supply
•
and with the accompanying table (Table 1).
Installation
Table 1
Mains voltage:
200V
208V
220V
230V
240V
380V
400V
415V
Selector B
200V-208V
200V-208V
220V-230V-240V
220V-230V-240V
220V-230V-240V
380V
400V-415V
400V-415V
40
Fig. 3.8
Cod.nº 429043