3.3.4. Transformer connection. Configuring the machine voltage

HS-6013/HS-6017 models
Disconnect and mechanically lock the external automatic switch.
Remove the support cover (A) from the junction box located on the rear panel (Fig. 3.8).
Connect the voltage selector (B) onto the transformer connector (C) in accordance with the power supply
and with the accompanying table (Table 1).
Installation
Table 1
Mains voltage:
200V
208V
220V
230V
240V
380V
400V
415V
Selector B
200V-208V
200V-208V
220V-230V-240V
220V-230V-240V
220V-230V-240V
380V
400V-415V
400V-415V