3.6. External signal. Connection

CAUTION!
Option available in Inteli Control models only.
To be able to use this option, the washing machine must be fitted with the A6 board, duly installed and activated
in the SETUP menu.
External signal. It is possible to use an order from the washing machine control to issue an end of program or
alarm warning.
See Inteli control Operation Manual for further information.
External signal specifications.
Free voltage contact between terminals X4-5 and X4-6 on the A6 board.
Maximum intensity allowed: 1A.
Maximum voltage: 240V.AC.

3.7. Tensioning belts

ATTENTION!
Excessive tightening will dramatically reduce the life of the motors and can cause
breakage of the pulley or the shaft.
A belt that is too slack can lead to jerky movements and cause damage to the belt itself.
To check the tension of the belts, apply a force in the centre of the
span of 5 kg (11 lb) and tighten until obtaining the values shown in
the table below.
NEW BELTS
HS-6013
10 mm (0.39 in)
EH030
HS-6017
7 mm (0.28 in)
EH040
HS-6023
18 mm (0.71 in)
EH055
HS-6024
9 mm (0.35 in)
EH060
HS-6028
9 mm (0.35 in)
EH070
HS-6032
9 mm (0.35 in)
EH080
Installation
BELTS
IN USE
12 mm (0.47 in)
9 mm (0.35 in)
20 mm (0.79 in)
10 mm (0.39 in)