Use the virtual function keys to page through the intervals and clear statistics.
7900-A2-GB21-20
CSS (Controlled Slip Seconds): Seconds during which one or more
controlled slips (as defined in TR 54016) occurred.
LOFC (Loss of Frame Count): Contains the number of times that an LOF is
declared.
Status: Contains the contents of the status events register. The status events
register maintains a history of specific events that have occurred during an
interval. Values include:
— Y: Remote alarm indication signal (yellow alarm) received at the DSX-1
interface
— L: Loss of signal detected at the DSX-1 interface
— E: Excessive error rate threshold exceeded
— F: Frame synchronization bit error detected
— V: Line code violation detected
— None: No significant events have occurred
This Field . . .
Contains . . .
Current Interval Timer
The number of seconds which have elapsed in the current
15-minute interval. Maximum value is 900 seconds
(15 minutes). This counter resets every 15 minutes.
Error Events Counter
A running total of CRC and OOF events. Total range =
0–65535. Counter resets when the statistics are cleared.
Current Int
Performance data for the current 15-minute interval.
Interval xx
Historical performance data for up to 96 15-minute intervals
(24 hours) where the value of xx is from 01 to 96.
Worst Interval
The number of the interval with the worst (highest) performance
data. If two or more intervals are equal, the oldest interval is
displayed.
Tot
A 24-hour running total.
December 2001
7. Monitoring and Troubleshooting
7-15