Paradyne 7974 User Manual page 143

Tdm sdsl standalone termination units
Table of Contents

Advertisement

Tests that affect the enterpriseTestStart and enterpriseTestStop traps and the
variable bindings depend on the interface. The specific tests and variable bindings
are described in the following table:
7900-A2-GB21-20
enterpriseTestStart/Stop
Interface
variable bindings
T
DSL Network
T
T
T
T
December 2001
B. Standards Compliance for SNMP Traps
ifIndex (RFC 1573)
ifAdminStatus (RFC 1573)
ifOperStatus (RFC 1573)
ifType (RFC 1573)
ifTestType (RFC 1573)
The following objects
control tests in
SNMP-managed devices:
– noTest(0) – Stops the
test in progress.
– testLoopLLB(4) –
Initiates a Local
Loopback.
– testSendMon511(6) –
Initiates a Send and
Monitor 511 test.
– testSendLLBUp(7) –
Initiates an LLB Up
message to the remote
unit.
– testSendLLBDown(8) –
Initiates an LLB Down
message to the remote
unit.
Possible Cause
T
enterpriseTestStart – Any
one of the following tests is
active on the interface:
– Line Loopback
– Remote Line Loopback
– Send and Monitor 511
T
enterpriseTestStop – No
tests currently running on the
interface.
B-7