Paradyne 7974 User Manual page 41

Tdm sdsl standalone termination units
Table of Contents

Advertisement

Procedure
To apply the downloaded firmware:
7900-A2-GB21-20
5. Position the cursor at the Start Transfer field. Use the spacebar to select Yes.
Press Enter.
When the data transfer is complete:
— If you selected Yes in Step 4, the unit is reset.
— If you selected No in Step 4, the Transfer Status field changes to
Completed successfully.
If you specified No (the default) in the Immediately Apply Download field in
Step 4 above, you must now apply the download.
main/control/apply_download
Switch To Code Revision A01.00.02: No
An answer of "yes" will cause the system
to reset as if it had been powered off and on!
-------------------------------------------------------------------------------
Ctrl-a to access these functions, ESC for previous menu
Select: Yes, No
1. Press the Escape key to return to the Control menu. Select Apply Download.
2. On the Apply Download screen, type Yes to reset the card and activate the
code.
Selecting Yes causes the termination unit to reset.
NOTE:
The termination unit has two flash memory banks to hold executable firmware.
You can switch between these two firmware versions by applying the firmware
listed on the Apply Download screen.
December 2001
3. Initial Startup and Configuration
APPLY DOWNLOAD
WARNING:
LOS at Net, Pt 1
Model: 797x
MainMenu
Exit
3-17

Advertisement

Table of Contents
loading

This manual is also suitable for:

79767975Hotwire 7974-a2Hotwire 7975-a2Hotwire 7976-a2

Table of Contents