Paradyne HotWire 7925 Correction User's Manual

E1 hdsl standalone termination unit errata
Hide thumbs Also See for HotWire 7925:

Advertisement

HotWire 7925 E1 HDSL Standalone Termination Unit
Errata
Document Number 7925-A2-GK40-00
August 1997
There is an error in the User's Guide (Document No. 7925-A2-GB20-30) that was detected after printing.
Please make note of the following correction.
Page C-4 shows the switchpack definitions for V.35-compatible units. In the table on the left for
Switchpack S1, the definition for Switch Position 1 is incorrect. The correct definition is:
Switch Position 1:
Switchpack S1
ON
1 2 3 4 5
6 7 8
Position
Settings*
1
OFF = CP
ON = CO
2
OFF = Loops A and B
ON = Loop A
3
unused
4, 5
00 or 11 = Internal
Clock
01 = External Clock
10 = Loop Clock
6, 7, 8
unused
* Default in bold
7925-A2-GK40-00
TM
OFF = CP
ON = CO (default setting)
P1 P2
S1
P4
P9
P10
HDSL Line Jack
Figure C-2. V.35-Compatible Unit Switchpack and Jumper Locations
August 1997
VT100 Terminal
Modular Jack
S2
P5
P8
P11
V.35
Switchpack S2
ON
1 2 3 4 5
6 7 8
Position
Settings*
1
ON = 64 kbps
2
ON = 128 kbps
3
ON = 192 kbps
4
ON = 256 kbps
5
ON = 384 kbps
6
ON = 512 kbps
7
ON = 768 kbps
8
ON = 1024 kbps
All ON = 64 kbps
All OFF = 2048 kbps
Jumper P8
Pins*
Settings*
1-2
Terminal Mode
2-3
Switchpack Mode