Operation
3.
The signed meter values are automatically transmitted to the backend systems of the charging point
operator and the invoicing partner. The invoicing partner is obligated to list the meter values including the
signature for each transaction on the invoice.
4.
Customers use the so-called transparency software to check their invoices. Together with the public key
and the signed invoicing data, the software enables them to check that the invoicing data have not been
falsified. The signed invoicing data is sent by E-mail to the end customers, the public key is located at the
top left of the name plate as QR code. The software and the instructions for its installation and use can be
found at https://safe-ev.org/en/transparency-software/e-mobilists/ or it is made available by the invoicing
partner. Version 1.1.0 shall be used.
Descriptions of the displays that are relevant under calibration law and their registers as well as the
description of the verification via public key can be found in the corresponding manual: https://
download.dzg-metering.de/DCMeter/manual/DZG-gsh-manual.pdf.
For the checking of the public key, see chapter "Identification", page 47
For mobile phones several apps are offered with which bar codes and DMC / QR codes can be read. How
a bar code is scanned on an Android device using the app "QR & Barcode Scanner" by Simple Design Ltd.
is described in the following. First the app from the Playstore must be installed on the smartphone. The
DMC of the DC energy meter's public key can be found on the name plate of the wallbox (see chapter
"Designations", page 15). To determine the public key as alphanumeric information, the DMC is scanned
with the installed app. If scanning does not start automatically, you can touch the arrow pointing to the
left that you can find on the app's start screen at the very top. During scanning, the camera frame must be
positioned so that it captures the DMC. The output window of the app then shows the decoded DMC. By
clicking on a corresponding icon in the app the alphanumeric text can be copied to the clipboard or sent as
text message or by E-mail.
7.7
Decommissioning
The DC Wallbox is designed for continuous operation. After initial commissioning it should only be switched
off for servicing purposes. For decommissioning, the power supply outside the DC Wallbox is interrupted. It
must be ensured that prior to that the vehicle has been disconnected from the charging station.
42
iONiX 25_DC-Wallbox_D00461_01_M_XXEN/01.2024
Need help?
Do you have a question about the iONiX Light 25 Wallbox and is the answer not in the manual?