Setting values
MagicCompact BA04
V 06/13
Problem/error/malfunction
Bad separation efficiency of the
cyclone
Sieve clogged up
Automatic floor blow-off system not
OK
Note:
The setting values for the powder center and other plant units you
will find in the corresponding operating instructions!
Procedures/remedy
Check all gaskets, above all, on the
powder separation of the cyclone and
if necessary, repair them
Check the exhaust air volume flow, if
necessary, clear blocked tubes or
repair the After Filter
Check the cyclone casing for holes,
caused by wear
Check the pretension force of the
closings
Check the powder for dampness
Check, if too much powder was fed
through the cyclone, e.g. during the
booth cleaning
Check, if the vibration motor is
switched on
Check, if the vibration is strong
enough
If necessary, adjust the oscillating
weights on the vibration motor
Check the compressed air supply
Pressure reducing valve defective or
adjusted incorrectly
Solenoid valve defective (coil, cable)
or missing signal