Functional check
MagicCompact BA04
V 06/13
General information
A function check is to be carried out:
After a replacement of spare parts on the booth or on the
-
electrical part of the booth, or on plant units connected to the
booth
After manipulations on the electrical part, or on external plant
-
units connected to the booth control unit, or on the booth
control unit itself
after long stops/standstills
-
Procedure of the function check
1. Switch on the main switch, control units and all interlocked
equipment should not be able to be switched on
2. Turn the key switch, the control unit is activated, the
operating unit is activated and the key switch returns to its
starting position. Control units and all interlocked equipment
should not be able to be switched on
3. Start the system, the main menu appears on the operating
unit, the fan in the powder center runs up
4. The operation of the powder center is described in the
corresponding user manual
5. If the powder container is positioned on the vibrating table in
the powder center, the coating function can be initiated. The
injectors move downwards and the level control unit is
activated. The vibrator and the fluidization are switched on
6. Switch on the gun control units
7. Activate the automatic function on the operating unit, the
reciprocators move to the reference point. All interlocked
plant units are enabled (ES control unit etc.)
8. The control units and all interlocked plant units are ready for
operation
9. The message "too little powder" appears on the operating
unit after a delay, and the alarm horn sounds