Maintenance - Gema MagicCompact BA04 Operating Instructions And Spare Parts List

Powder coating booth
Table of Contents

Advertisement

Maintenance

Maintenance and repair
MagicCompact BA04
V 06/13
Daily or after each shift
Blow off the powder hoses
-
Clean the guns externally and the check wearing parts
-
Check the vibrating sieve of the cyclone separator and clear
-
away contamination with an industrial vacuum cleaner
Weekly
(in single-shift works, or in each fifth shift in multi-shift works)
Check the clean air chamber in the After Filter housing for
-
powder deposits through the inspection window of the filter
housing above the door. If powder deposits are present, this
is an indication of defect filter elements (replace the filter
elements, see After Filter operating instructions).
Check all oil separators and if necessary, empty (if oil is
-
present, the compressed air preparation must be checked)
Biannually
Disconnect the measuring lines of the pressure gauges on
-
the manometer, and blow it off from the manometer to the
measuring point (beginning of the line). H = high, L = low
Note:
The indicated blowing direction is absolutely to be observed!
The parts to be replaced during maintenance are available as spare
parts, see the spare parts list!