Operational Problems; Troubleshooting - FAAC B680H Operating Instructions Manual

Hide thumbs Also See for B680H:
Table of Contents

Advertisement

10.4 OPERATIONAL PROBLEMS

 15 Troubleshooting
CONDITION
The barrier does not perform the SETUP
The barrier does NOT OPEN
The barrier CLOSES rather than OPENING and vice versa.
The barrier makes very slow movements
The barrier moves irregularly
The barrier does NOT OPEN
The barrier does NOT CLOSE
The barrier does NOT OPEN and does NOT CLOSE
The barrier moves irregularly and is very noisy during the
opening and closing cycles
B680H
FINDING SOLUTIONS
Make sure that the automation has not been released
Make sure there is power
Check the motor and encoder connection
Invert the phases in the motor connection and carry out the setup
Check the force set
Make sure that the beam is balanced
Make sure that the parameter
the beam
If the barrier working on the battery, make sure that the battery is charged.
Check the motor connection and make sure that the encoder is working
correctly
Make sure that the automation has not been released
Check the driving direction of the motor
Make sure that the automation has not been released
Check the driving direction of the motor
Check the LED status of the controls, loops, safety devices and EMR are not
active
Make sure that the automation has not been released
Check the status of the STOP LED is not active
Check the motor and encoder connection
Make sure there is no air in the hydraulic circuit, bleed it if necessary.
64
cF
has been set according to the length of
732719 - Rev.E

Advertisement

Table of Contents
loading

Table of Contents