Basic Programming - FAAC B680H Operating Instructions Manual

Hide thumbs Also See for B680H:
Table of Contents

Advertisement

 3 Basic programming
Basic function
] [ Simply Connect
0
disabled
1
enabled
2 , 3 , 4 not used
cF BARRIER CONFIGURATION
01...06 (levels)
i
To establish this value, refer to § 5.2. Setting a default
value that is lower than the one actually installed can
cause irreversible damage to the beam and to the struc-
ture of the barrier. Loading a different configuration will
reset the parameters to the default values.
dF DEFAULT CONFIGURATION
Displays Y if the programming corresponds to the
default settings. Select Y if you wish to reload
the default values.
Y
the programming corresponds to the
DEFAULT settings
no the programming does NOT correspond to
the default settings
Ct OPPOSING BARRIER CONFIGURATION
Configure the board as Primary or Secondary.
MA
Primary
SL
Secondary
i
The following parameters are not displayed on the
Secondary board SC-bu-LO-PA-L1-L2-tL-PF-
tP-t (for further information see § 8.1).
bu BUS 2easy DEVICE LEARNING
See the relative section.
LO FUNCTIONING LOGIC
A
Automatic
A1
Automatic 1
E
Semi-automatic
P
Car park\
PA
Automatic Parking
i
Parameter CU is only displayed if a modification has
been made to the advanced programming parameters.
PA PAUSE TIME
00...59 Adjustment step: 1 s
1.0...4.1 Adjustment step: 10 s
So OPENING SPEED
01...10 (minimum speed ... maximum speed)
B680H
Default
0
06
Y
MA
no
E
Cn
Condominium
CA
Automatic condominium
C
Hold-to-run
CU
Custom (logic created
in expert programming
mode)
20
10
Basic function
Sc CLOSING SPEED
01...10 (minimum speed ... maximum speed)
*The default value varies according to the setting
of cF:
10
if cF=01
05
if cF=02 or 03
04
if cF=04
02
if cF=05 or 06
i
Setting an excessive speed can cause irreversible damage
to the beam and to the structure of the barrier.
L1 LOOP1
Loop connected to input LOOP1 (OPEN function).
Y
LOOP1 enabled
no
LOOP1 not enabled
L2 LOOP2
Loop connected to input LOOP2 (SAFETY/ CLOSE
function).
Y
LOOP2 enabled
no
LOOP2 not enabled
S1 Sensitivity LOOP1
Regulates the sensitivity of the vehicle detection
loop
00...10 (sensitivity levels, 10 = maximum
sensitivity)
S2 Sensitivity LOOP2
Regulates the sensitivity of the vehicle detection
loop
00...10 (sensitivity levels, 10 = maximum
sensitivity)
Mt MOTOR OPERATION IN DEAD MAN MODE
+ +
OPENS (displaying oP) as long as the button
remains pressed.
CLOSES (displaying cL) as long as the button
- -
remains pressed.
tL SETUP
Acquire the limit switch positions. See the
relative section.
30
Default
02
*
no
no
05
05
--
--
732719 - Rev.E