 10 Addressing BUS 2easy control devices
Key: 0=OFF , 1=ON
DIP switch 5, if present, in the ON position enables the device for
2 commands.
ON
1 2 3 4 5
0 0 0 0 0 Open A_1
0 0 0 1 0 Open A_2
0 0 1 0 0 Open A_3
0 0 1 1 0 Open A_4
0 1 0 0 0 Open A_5
0 1 0 1 0 Stop
0 1 1 0 0 *Stop NC_1
0 1 1 1 0 *Stop NC_2
1 0 0 0 0 Close
1 0 0 1 0 /
1 0 1 0 0 /
1 0 1 1 0 /
1 1 0 0 0 /
1 1 0 1 0 /
1 1 1 0 0 /
1 1 1 1 0 /

REGISTERING BUS 2EASY DEVICES

Registration is required:
- when the automation system is first started or after
the board has been replaced
- following any changes (addition, replacement or
removal) to the BUS 2easy devices
Registration procedure BUS 2easy:
1. With the board powered, go to the
basic programming.
+ +
and - - buttons simultaneously for
2. Press the
at least 5 s. The display flashes, then
(registration complete).
3. Release the buttons and exit from programming
mode.

CHECKING THE BUS 2EASY STATUS LEDS

To verify the BUS 2easy connection and status, check
the LEDs on the board:
At least one device is in operation
DL1
NO devices in operation
(RED)
BUS 2easy registration in progress
DL2
OK
(GREEN)
SLEEPING
SHORT CIRCUIT
ERROR
B680H
ON
1 2 3 4 5
0 0 0 0 1 Open A_1 /
0 0 0 1 1 Open A_1 /
0 0 1 0 1 Open A_1 Stop
0 0 1 1 1 Open A_1 Close
0 1 0 0 1 Open A_2 /
0 1 0 1 1 Open A_2 /
0 1 1 0 1 Open A_2 Stop
0 1 1 1 1 Open A_2 Close
1 0 0 0 1 Open A_3 /
1 0 0 1 1 Open A_3 /
1 0 1 0 1 Open A_3 Stop NC_1
1 0 1 1 1 Open A_3 Close
1 1 0 0 1 Open A_4 /
1 1 0 1 1 Open A_4 /
1 1 1 0 1 Open A_4 *Stop NC_2
1 1 1 1 1 Open A_4 Close
bu
function in
Y
appears

VERIFYING BUS 2EASY DEVICES

bu
1. Go to the
function in basic programming. The
display shows status BUS 2easy:
no
No devices are registered
-
At least one device registered
cc
BUS 2easy short circuit / overload (error 36)
BUS 2easy line error (check the addresses and repeat
Er
the registration)
+ +
2. Press the
button and keep it pressed; the seg-
ments relative to the registered devices turn
on. Release the button, the display reverts to the
BUS 2easy status view.
3. To check the operation of the registered devices,
activate each device individually and check that
the corresponding segment lights up.
7
1
2
3
1
Open A control device
2
Not used
3
Closing photocells
4
Photocells for Open impulse
5
Not used
6
Close control device
7
Not used
8
Stop control device
9
Not used
10
Not used
11
Not used
12
Not used
13
BUS 2easy status
14
Not used
15
Not used
16
Not used
88
88
e.g. 1 or more OPEN A control devices and
closing photocells are registered
48
6
8
14
12
5
11
4
15
9
10
16
732719 - Rev.E