 5 Expert Programming
Expert Function
01
Enabling this function causes automatic closing after the pause time.
If you enable this function, operation is with two different inputs:
02
OPEN for opening and CLOSE for closing.
Level recognition activation for the OPEN and CLOSE inputs (maintained command). I.e.
the board recognises the level (for example, if STOP is pressed with maintained OPEN, when
03
STOP is released, the automation continues to open).
If 03 is disabled, the board commands a movement only in response to a change in the input.
Activation of DEAD MAN opening (command kept pressed). Releasing the OPEN command
04
stops operation
If you enable this function, an OPEN command during opening stops the movement.
If parameter 06 = no the system is ready for opening.
05
If parameter 06 = Y the system is ready for closing.
If you enable this function, an OPEN command during opening reverses movement.
06
If parameters 05 and 06 = no, the OPEN command has no effect during opening.
If you enable this function, an OPEN command during a pause stops the movement.
07
If parameters 07 and 08 = no, the OPEN command reloads the pause time.
If you enable this function, an OPEN command during the pause closes the automation.
08
If parameters 07 and 08 = no, the OPEN command reloads the pause time.
If you enable this function, an OPEN command during closing stops the operation, otherwise
09
it reverses the movement.
DEAD MAN closing enable (command kept pressed). Releasing the CLOSE command
10
stops the movement.
If you enable this function, a CLOSE command has priority over OPEN, otherwise OPEN has
11
priority over CLOSE.
If you enable this function, a CLOSE command closes the automation when released. The
12
unit remains in closing pre-flashing as long as CLOSE is enabled.
If you enable this function, a CLOSE command during opening stops operation, otherwise
13
the CLOSE command causes the automation to reverse immediately or at the end of opening
(see also parameter 14)
If you enable this function, and if parameter 13 = no, the CLOSE command closes the auto-
14
mation immediately at the end of the opening cycle (memorises the CLOSE). If parameters
13 and 14 = no, CLOSE causes the automation to close immediately.
If you enable this function when the system is stopped by a STOP command, a subsequent
15
OPEN command causes the automation to move in the opposite direction. If parameter
15 = no it always closes.
If you enable this function, during closing, the CLOSING SAFETIES stop movement and
16
allow it to resume once they are released, otherwise it immediately reverses in opening.
If you enable this function, the SAFETIES IN CLOSING close the automation when released
17
(also see parameter 18).
If you enable this function, and if parameter 17 = Y, the unit waits for the opening cycle to
18
end before carrying out the closing command issued by the SAFETIES IN CLOSING.
B680H
34
Setting
Y = automatic closing
no = disabled
Y = operation with 2 inputs
no = disabled
Y = level recognition
no = status change recognition
Y = enabled
no = disabled
Y = stop movement during ope-
ning
no = disabled
Y = reverse movement during
opening
no = disabled
Y = stop movement during pause
no = disabled
Y = close in pause
no = disabled
Y = stop
no = reverse
Y = enabled
no = disabled
Y = enabled
no = disabled
Y = close when released
no = close immediately
Y = CLOSE stops movement
no = CLOSE reverses movement
Y = close at the end of opening
no = close immediately
Y = move in the opposite direction
no = always close
Y = close when released
no = reverse immediately
Y = close when FSW is released
no = disabled
Y = close at the end of opening
no = disabled
732719 - Rev.E