Primary / Secondary Configuration - FAAC B680H Operating Instructions Manual

Hide thumbs Also See for B680H:
Table of Contents

Advertisement

PRIMARY / SECONDARY CONFIGURATION

1. Switch power on to the barriers.
2. On both boards, carry out programming according
to the beam configuration and length (
Programming).
3. Set:
Ct
MA
-
=
on the primary board
Ct
SL
-
=
on the secondary board
i
The operating logic should only be programmed on the
Primary board.
4. Check the status of the LEDs on the boards and
make sure that LED DL2 (green) is lit.
5. Check the driving direction for both barriers (see
§ 5.4).
6. Bring the automations to the fully closed position
using parameter Mt in BASIC programming.
7. Access Basic programming on the Primary board
and select parameter
buttons at the same time until both automation
systems start to open slowly. The
flashes on the display
B680H Primary
DL2
+
11
12 13 14 15 16 17 18 19
3 4 5 6 7 8 9
10
2EASY
B680H
cF
in Basic
tL
+ +
and - -
, then press the
--
symbol
.
CAL1 CAL2
M.A.
-
F
20
21
24 25 26 27
8. On reaching the fully open position, both automa-
tion systems will stop automatically.
9. The automation systems will then begin the beam
closing movement.
10. On reaching the closed position, the movement
will stop automatically.
11. Press the F button to exit the procedure and
confirm that you wish to save the data using
St
parameter
.
12. Check that the current status of the automation
shown on the display of both automation systems
00
is
(closed) and that the beam is in the closed
position.
i
During setup the Primary board controls the Second-
ary board.
When a device is configured as Secondary, the unused
parameters will be hidden in the programming menus.
DL2
3 4 5 6 7 8 9
2EASY
55
B680H Secondary
CAL1 CAL2
S.L.
+
-
F
11
12 13 14 15 16 17 18 19
20
21
24 25 26 27
10
732719 - Rev.E
38

Advertisement

Table of Contents
loading

Table of Contents