Operator Function
CLEAR NVRAM
▶ To clear NVRAM on the ATM, begin by entering the Operator Function Menu using the
Master Password. Then enter SYSTEM SETUP, SYSTEM CONTROL and CLEAR
NVRAM in sequence.
1. CLEAR ALL
This will delete all programmed parameters and make all setting information
(including passwords) to the default settings. This does NOT include the master keys
which are stored in EPP.
2. CLEAR SETTING
This will delete all programmed parameters and make all information (including
passwords) to the default settings. This does NOT include the master keys which are
stored in EPP, denomination, journal data.
3. CLEAR JOURNAL
This will delete all journal data permanently
4. CLEAR TRANS. SEQUENCE NO.
This function will reset the journal sequence number to <0000>. This may be useful if
you switch processing or switch Terminal ID numbers and want to keep new records.
5. CLEAR LOG
This will delete all logs permanently
<Note!>
Be careful when using these features (NVRAM clearing) – The initialized data can NOT
be recovered.