System Factory Default; Outputs And Sirens; Outputs - Bosch AMAX panel 2100 Installation Manual

Hide thumbs Also See for AMAX panel 2100:
Table of Contents

Advertisement

AMAX panel
For an overview of the possible faults and tampers and how to solve them, see Trouble Fault
Inquiry, page 144.
FW Version
This option displays the current firmware version.
6.5.3

System Factory Default

The system can be reset to the factory default settings either via software or via hardware.
Recorded voice messages are not automatically deleted when the system is reset to the
factory default setting. Voice messages have to be deleted separately. Therefore, refer to Voice
Default, page 73.
How to reset the system to the factory default settings via software
Default panel
This option resets the system to the factory settings.
4
P
Default only with installer
This option enables/disables the possibility to reset the system via hardware. If this option is
enabled, the system can not be reset via hardware any more.
How to reset the system to the factory default settings via hardware
The system can be reset to factory default settings with the 'resetting to factory default' pads
at the top on the printed circuit board on the main board of the AMAX panel if this possibility
is enabled in the software.
1.
2.
3.
P
Notice!
If the default pads are short-circuited for over 10 seconds after power-up, the AMAX panel
discards resetting to factory default.
6.6

Outputs and Sirens

6.6.1

Outputs

Onboard / Extension Output
The AMAX panel is equipped with on-board outputs and supports DX3010 output extension
modules with each extension module supporting 8 relay outputs.
When on-board output 1 or 2 fails due to a short circuit or an open circuit, as long as there is a
backup power supply, the output fault will not affect the normal operation of the whole
system, but will be detected by the system.
Each output is programmable and can be set to follow multiple events.
Bosch Sicherheitssysteme GmbH
All manuals and user guides at all-guides.com
Select DEFAULT PANEL YES if you really want to reset the system or select DEFAULT
PANEL NO if you don't want to reset the system.
All programming parameters and recorded voice messages are reset to factory default.
Disconnect the AC power supply and the backup battery.
Short-circuit the 'resetting to factory default' pads.
Power up the system.
Quick flash of the red LED indicator on the printed circuit board of the AMAX panel
indicates that the factory default is reset.
All programming parameters and recorded voice messages are reset to factory default
immediately after releasing the short-circuited bonding pads.