Bosch AMAX panel 2100 Installation Manual page 65

Hide thumbs Also See for AMAX panel 2100:
Table of Contents

Advertisement

AMAX panel
Unverified alarm
report / cross zone
Domestic no.
Zone Bypass
If this option is enabled, the operator can bypass zones before arming the system. If this
option is disabled, manual bypass of the zone is not available. After manual bypass of the
zone, a zone bypass report is sent.
The zone bypass is valid in only one arming period and will be resumed after disarming. Before
disarming, the bypassed zones ignore all zone triggering and restoration events.
The key switch zone cannot be bypassed.
Forced Arming
If this option is selected, the system can be armed when the zone is in triggering status. If this
option is not selected, the system does not allow the user to arm the system unless the zone
with problems has resumed to normal status or been manually bypassed.
Bosch Sicherheitssysteme GmbH
All manuals and user guides at all-guides.com
1
Receiver 1
2
Receiver 2
3
Receiver 3
4
Receiver 4
5
Receiver 1, 2, 3, and 4
6
Receiver 1 (2, 3, and 4 for backup)
7
Receiver 1 (2 for backup) and receiver 3 (4 for backup)
0
Disabled
1
Unverified alarm report
2
Cross zone
3
All
Follow 'alarm report' option's logic. range 0-7
0
No reports allowed
1
Report to destination 1
2
Report to destination 2
3
Report to destination 3
4
Report to destination 4
5
Report to destination 1 ,2, 3, 4
6
Report to destination 1 (2, 3, and 4 for backup)
7
Report to destination 1 (2 for backup) and 3 (4 for
backup)
8
Report to destination 1, 2
9
Report to destination 1 (2 for backup)
10
Report to destination 3, 4
11
Report to destination 3 (4 for backup)
Installation Manual