Bosch AMAX panel 2100 Installation Manual page 152

Hide thumbs Also See for AMAX panel 2100:
Table of Contents

Advertisement

152
en | Troubleshooting
1.
2.
Restore:
4
Supervise:
1.
2.
P
Condition:
The repeater is in a low battery condition if a wireless module is enabled.
Restore:
4
Supervise:
1.
2.
P
Condition:
The sensor is in a low battery condition if a wireless module is enabled.
Restore:
4
Supervise:
1.
2.
P
Condition:
The keyfob is in a low battery condition if a wireless module is enabled.
Restore:
4
Supervise:
1.
2.
P
3 -Output Failure
2015.05 | 06 | F.01U.309.277
All manuals and user guides at all-guides.com
AC power failure to the repeater.
The repeater is not wired correctly, if a wireless module is enabled.
Restore the repeater AC power and reset the fault.
Report the repeater AC power fault to configured destination when the fault is detected.
Slow flash FAULT indicator (refer to Keypad Indicators, page 8 for a detailed description).
When the fault is reset, send the restored report to the configured destinations.
The FAULT indicator is turned off when there is no other system fault.
RF Repeater 1-8 Battery Failure
Restore the repeater battery and reset the fault. For more information refer to RF Devices,
page 83.
Report the repeater battery fault to configured destination when the fault is detected.
Slow flash FAULT indicator (refer to Keypad Indicators, page 8 for a detailed description).
When the fault is reset, send the restored report to the configured destinations.
The FAULT indicator is turned off when there is no other system fault.
RF Sensor Power Failure
Restore the sensor battery and reset the fault. For more information refer to RF Devices,
page 83.
Report the sensor power fault to configured destination when the fault is detected.
Slow flash FAULT indicator (refer to Keypad Indicators, page 8 for a detailed description).
When the fault is reset, send the restored report to the configured destinations.
The FAULT indicator is turned off when there is no other system fault.
RF Keyfob Battery Failure
Restore the keyfob battery and reset the fault. For more information refer to RF Devices,
page 83.
Report the keyfob battery fault to configured destination when the fault is detected.
Slow flash FAULT indicator (refer to Keypad Indicators, page 8 for a detailed description).
When the fault is reset, send the restored report to the configured destinations.
The FAULT indicator is turned off when there is no other system fault.
Onboard Output 1-2 Fault
Installation Manual
AMAX panel
Bosch Sicherheitssysteme GmbH

Advertisement

Table of Contents
loading

This manual is also suitable for:

Amax panel 3000Amax panel 3000 beAmax panel 4000

Table of Contents