Bosch AMAX panel 2100 Installation Manual page 78

Hide thumbs Also See for AMAX panel 2100:
Table of Contents

Advertisement

78
en | Settings
In case of a new alarm, the output time will be reset.
If the output time is set to 000, the output will continue until the zone is restored or the
system is disarmed.
04 - System Alarm (audible and silent)
This output is operated in case of an audio alarm of the system:
This output also operates in case of a silent alarm of the system:
The output is reset in the following cases:
In case of a new alarm, the output time will be reset.
If the output time is set to 000 and the alarm siren sounds time to 0, the output will continue
until the alarm output is reset or the system is disarmed by entering your code + [3] [2] + [#].
The output of the following system alarms is only one second:
05 - External AWAY Siren
The output is operated in the following cases:
(No output is operated when the system is disarmed.)
06 - External STAY Siren
The output is operated in the following cases:
(No output is operated when the system is disarmed.)
07 - Internal Siren
The output is operated in the following cases:
2015.05 | 06 | F.01U.309.277
All manuals and user guides at all-guides.com
The programmed output time ends.
Zone (alarm or tamper) programmed to disable zone silent alarm
System tamper / DX2010 tamper / keypad tamper
Keypad alarm (emergency alarm, fire alarm, medical aid alarm)
Zone (alarm or tamper) programmed to enable zone silent alarm.
The alarm is reset.
The system is armed.
The system is disarmed.
Alarm siren test
Pacing (tamper / alarm / reset)
Key switch arming or locking key switch disarming
The system is in AWAY mode and a zone intruder alarm (intruder alarm = instant / interior
instant / delay / interior delay / delay exit / interior delay exit / follower / interior
follower / 24h (can be silenced) / fire (can be silenced) / technical alarm (can be
silenced)) occurs.
The system is in AWAY mode and a tamper alarm occurs.
The system is in STAY mode and a zone intruder alarm (intruder alarm = instant / interior
instant / delay / interior delay / delay exit / interior delay exit / follower / interior
follower / 24h (can be silenced) / fire (can be silenced) / technical alarm (can be
silenced)) occurs.
The system is in STAY mode and a tamper alarm occurs.
The system is in AWAY mode and a zone intruder alarm (intruder alarm = instant / interior
instant / delay / interior delay / delay exit / interior delay exit / follower / interior
follower / 24h (can be silenced) / fire (can be silenced) / technical alarm (can be
silenced)) occurs.
The system is in AWAY mode and a tamper alarm occurs.
Installation Manual
AMAX panel
Bosch Sicherheitssysteme GmbH

Advertisement

Table of Contents
loading

This manual is also suitable for:

Amax panel 3000Amax panel 3000 beAmax panel 4000

Table of Contents