System; System Setting - Bosch AMAX panel 2100 Installation Manual

Hide thumbs Also See for AMAX panel 2100:
Table of Contents

Advertisement

AMAX panel
6.5

System

6.5.1

System Setting

This chapter describes the system settings that can be accessed via the SYSTEM SETTINGS 1
and the SYSTEM SETTINGS 2 menu and their submenus if available.
Date and Time
The AMAX panel has a 24-hour clock and a 12-month calendar that need to be set after power
up. The order is day, month, year, hour, and minute, with each item occupying two digits [DD]
[MM] [YY] [HH] [MM].
Fault Configuration
Fault Sound Reminder
When the command [2] [1] is used for fault inquiry, the keypad can be programmed to sound
prompt tone to indicate new system fault. The system is defaulted to enable. In case of a new
fault, all keypads will sound a short beep once a minute.
AC Fault Delay Time
The fault report to display on the keypad will be delayed for the selected time (01 – 98
minutes; default = 60 minutes; disabled = 99).
Date/Time Fault
In case of date/time settings fault, it is possible to choose to display the fault or transmit fault
prompt tone at the same time, or to not display and stop fault prompt tone. If it is chosen to
not display, the fault prompt tone is set, and the system will prompt nothing if no date and
time are set after power-up.
Battery Check Interval
This option defines the time interval in which the battery test is carried out (01 – 15 minutes;
00 = disabled). The battery test is also carried out when the system is armed or during system
power up.
Phone Line Monitor
If this option is enabled, the system supervises whether the phone line is broken or
disconnected.
Siren Supervision
If this option is enabled, the system supervises whether the siren is shortened or
disconnected.
AC Fault Auto Reset
This option enables/disables the automatic AC fault reset function.
If this option is enabled, an AC fault indication is restored automatically after the AC power
supply is restored.
If this option is disabled, an AC fault indication has to be reset manually after the AC power
supply is restored.
Communication Fault Auto Reset
This option enables/disables the automatic communication fault reset function.
If this option is enabled, a communication fault indication is restored automatically after the
communication is restored.
If this option is disabled, a communication fault indication has to be reset manually after the
communication is restored.
Phone Fault Auto Reset
This option enables/disables the automatic phone fault reset function.
Bosch Sicherheitssysteme GmbH
All manuals and user guides at all-guides.com
Installation Manual
Settings | en
71
2015.05 | 06 | F.01U.309.277