8.6.2

Siren Programming

Option
Beep for warning devices (0 = disabled, 1 = enabled)
Internal siren beep as indication (0 = disabled, 1 =
enabled)
Silence warning device when disarmed (0 = disabled, 1 =
enabled)
8.7

RF Device Programming

RF Options
Option
Printer functionality (0 = disabled, 1= enabled)
RF receiver functionality (0 = disabled, 1= enabled)
RF supervision interval (0 = disabled, 1 = 20 min, 2 = 1h, 3
= 2h, 4 = 4h, 5 = 12 h, 6 = 24h)
RF jam detect level (00 - 15, 00 = disabled, 01 = most
sensitive, 15 = least sensitive)
RF device low level battery resound (0 = disabled, 1 = 4h,
2 = 24h)
Siren beep arm/disarm (RF keyfob) (0 = disabled, 1=
enabled)
Keyfob panic option (0 = no alarm, 1 = silent alarm, 2 =
sound alarm)
RF missing as alarm (0 = disabled, 1= enabled)
Wireless Zone RFID
RFID for
wireless
zone no.
1
2
3
4
5
Bosch Sicherheitssysteme GmbH
All manuals and user guides at all-guides.com
Address
Default
(ten
digits, 15
= not in
use)
5256 – 5265
15
5266 – 5275
15
5276 – 5285
15
5286 – 5295
15
5296 – 5305
15
Installation Manual
Address Programming | en
Address
1600
1611
1605
Address
0991
0948
0949
0950
0951
0952
0953
0954
RFID for
Address
wireless
zone no
33
5576 – 5585
34
5586 – 5595
35
5596 – 5605
36
5606 – 5615
37
5616 – 5625
2015.05 | 06 | F.01U.309.277
139
Default
1
0
1
Default
0
0
4
EN=2
12
2
1
0
1
Default
(ten
digits, 15
= not in
use)
15
15
15
15
15

Advertisement