Bosch Solution 880 Operating Manual
Hide thumbs Also See for Solution 880:
Table of Contents

Advertisement

CC408
Operators Guide
EN
Solution 880

Advertisement

Table of Contents
loading

Summary of Contents for Bosch Solution 880

  • Page 1 CC408 Operators Guide Solution 880...
  • Page 2 This equipment is set up to carry out test calls at pre- determined times. Such test calls interrupt any other Bosch Security Systems Pty Ltd reserves the right to calls that may be set up on the line at the same time.
  • Page 3: Table Of Contents

    AC Fail ............12 Figure 7: Basic Pager Display ........ 19 12.2 System Faults ..........12 12.3 Fault Descriptions...........12 Telco Arm/Disarm Sequence (Call Forward On/Off) ............13 13.1 Telco Arm Sequence........13 13.2 Telco Disarm Sequence.........13 Turning Outputs On/Off.......14 Bosch Security Systems | 5/04 | 920050O.OG.112...
  • Page 4 Fault Condition Indicators .....12 Table 11: Telco Arm/Disarm Dialling Digits..13 Table 12: Domestic Dialling Telephone Digits ..16 Table 13: Zone Status Display Descriptions..18 Table 14: System Status ...........18 Table 15: Glossary of Terms ........20 Bosch Security Systems | 5/04 | 920050O.OG.112...
  • Page 5: Introduction

    Introduction Features Congratulations on selecting the Solution 880 Model The Solution 880 Control Panel uses the latest in CC408 Control Panel to protect you and your microprocessor technology to provide you with more property. To obtain the most from your unit, take the...
  • Page 6: Codepad Indicators

    Zone is sealed. Flashing Fast Zone is in alarm condition. (0.25 seconds on/ 0.25 seconds off) Flashing Slow Zone is manually isolated or (1 second on/ selected to be isolated. 1 second off) Bosch Security Systems | 5/04 | 920050O.OG.112...
  • Page 7: Mains Indicator

    STAY Mode 1. generated by the codepad buzzer. STAY Mode 2 Arms all zones except those programmed to be automatically isolated by the Master Code holder. See Section 5.3 Arming in STAY Mode 2. Bosch Security Systems | 5/04 | 920050O.OG.112...
  • Page 8: Arming In Away Mode

    [2 5 8 0 #]) before the entry timer expires, the sirens zones except 24-hour zones when the system is activate into alarm. Only your installer can program armed in STAY Mode 1 or STAY Mode 2. this option. Bosch Security Systems | 5/04 | 920050O.OG.112...
  • Page 9: Programming Stay Mode 2 Zones

    Up to eight user codes can be programmed to Two beeps sound and the STAY and AWAY operate the system. indicators turn dark. To delete other user codes, repeat this procedure as many times as required. Bosch Security Systems | 5/04 | 920050O.OG.112...
  • Page 10: Radio Transmitter Operations

    These indications allow you to operate the system from outside the premises with confidence. Bosch Security Systems | 5/04 | 920050O.OG.112...
  • Page 11: Fire Alarm

    [*] key. Repeat Step 2 if you are isolating more than one zone, until all zones to isolate are selected. Bosch Security Systems | 5/04 | 920050O.OG.112...
  • Page 12: Fault Analysis Mode

    This type of fault does not cause the FAULT indicator to display on the codepad unless your installer has programmed the automatic arming time. See Section 11. Setting the Date and Time to program the date and time. Bosch Security Systems | 5/04 | 920050O.OG.112...
  • Page 13: Telco Arm/Disarm Sequence (Call Forward On/Off)

    [3] and [#] keys (for example, [2 5 8 0 3 #]). Three beeps sound and the STAY and AWAY indicators flash. 2. Press button [1] and [#] keys to select the Telco Arm Sequence. Three beeps sound. Bosch Security Systems | 5/04 | 920050O.OG.112...
  • Page 14: Turning Outputs On/Off

    The system sends a Test Report without sounding the sirens. • Zone 1: Area 1 codepad • Zone 2: Area 2 codepad • Zone 7: master partitioned codepad Bosch Security Systems | 5/04 | 920050O.OG.112...
  • Page 15: Event Memory Recall

    How to Turn Day Alarm Off Hold down the [4] key until two beeps sound. Day alarm turns off. Bosch Security Systems | 5/04 | 920050O.OG.112...
  • Page 16: Domestic Dialling

    2. Press the [*] button followed by the [4] and [#] in the event of an alarm. keys (for example, [* 4 #]). The STAY and AWAY indicators go dark. Bosch Security Systems | 5/04 | 920050O.OG.112...
  • Page 17: Partitioning

    This indicator displays the status of the AC mains supply. The indicator lights steadily when the AC is You can partition or split the Solution 880 Control normal and flashes when there is an AC supply Panel into two individual areas. You can operate failure.
  • Page 18: Basic Pager Reporting

    Zone Trouble Indicates a zone was left unsealed after the end of exit time. Bosch Security Systems | 5/04 | 920050O.OG.112...
  • Page 19: Figure 7: Basic Pager Display

    4 – 0: Zone Normal 7 – 0: AC Normal 1: Alarm 1: AC Failure 2: Zone Bypassed 8 – 0: System Normal 3: Zone Trouble 1: System Fault 5 – 8: Disarmed 9: Armed Bosch Security Systems | 5/04 | 920050O.OG.112...
  • Page 20: Glossary Of Terms

    The control panel can recognise that detection devices may have stopped working or that the view to a PIR detector is blocked (unable to detect any movement over the duration of the time programmed by your installer). Bosch Security Systems | 5/04 | 920050O.OG.112...
  • Page 21 User Code The personal identification number that the operator uses to arm and disarm the system. Zones A monitored input used to trigger an alarm condition when violated. Bosch Security Systems | 5/04 | 920050O.OG.112...
  • Page 22: Installation Notes

    CC408 | Operators Guide | 25. Installation Notes EN | 22 25. Installation Notes Company Name Technician’s Name Technician’s Telephone Number Installation Date Warranty Expires Panel Software Version Service Notes Bosch Security Systems | 5/04 | 920050O.OG.112...
  • Page 23 User Code 11 User Code 4 User Code 12 User Code 5 User Code 13 User Code 6 User Code 14 User Code 7 User Code 15 User Code 8 User Code 16 Bosch Security Systems | 5/04 | 920050O.OG.112...
  • Page 24 Domestic Reporting Domestic Reporting – Number Of Beeps Other System Information Siren Run Time Minutes Sensor Watch Time Increments in Days Can Your System Be Serviced By Another Technician If Yes, Installer’s Code Bosch Security Systems | 5/04 | 920050O.OG.112...
  • Page 25 Off Indicator............7 On Indicator............7 STAY Indicator............6 Isolating System Disarmed ............ 6 Isolating Zones 11 Zone Indicators ............6 Code to Isolate ............11 Communciation Fail Standard Isolating ..........11 Communication Fail Bosch Security Systems | 5/04 | 920050O.OG.112...
  • Page 26 Adding Radio Users..........9 Deleting ..............9 Sealed 20 Sensor Watch Sensor Watch Fail Walk Test Silent Alarm Speaker Beeps 10 Status Indicators 17 Zone Indicators 6, 17 STAY Indicator 6 Zones 21 Bosch Security Systems | 5/04 | 920050O.OG.112...
  • Page 27 CC408 | Operators Guide | Notes EN | 27 Notes: Bosch Security Systems | 5/04 | 920050O.OG.112...
  • Page 28 Bosch Security Systems 25 Huntingwood Drive Huntingwood NSW 2148 Australia Phone: +612 9672 1777 Facsimile: +612 9672 1717 © 2003 Bosch Security Systems S1920050 Issue 112 4998152467B...