10-2/1 E (3 AC 400 V)
20-1/1 E (3 AC 400 V)
20-2/1 E (3 AC 400 V)
6-1/1 E (3 AC 415 V)
6-2/1 E (3 AC 415 V)
10-1/1 E (3 AC 415 V)
10-2/1 E (3 AC 415 V)
20-1/1 E (3 AC 415 V)
20-2/1 E (3 AC 415 V)
6-1/1 E (3 AC 440 V)
6-2/1 E (3 AC 440 V)
10-1/1 E (3 AC 440 V)
10-2/1 E (3 AC 440 V)
20-1/1 E (3 AC 440 V)
20-2/1 E (3 AC 440 V)
6-1/1 E (3 ph 440 V)
6-2/1 E (3 ph 440 V)
10-1/1 E (3 ph 440 V)
10-2/1 E (3 ph 440 V)
20-1/1 E (3 ph 440 V)
20-2/1 E (3 ph 440 V)
6-1/1 E (3 AC 480 V)
80.06.070_iCombiPro-iCombiClassic_IM_en-GB
Hz
Current
consump-
tion (A)
50/60
54
50/60
53.7
50/60
98
Hz
Current
consump-
tion (A)
50/60
15
50/60
33.7
50/60
28.5
50/60
56.5
50/60
56.2
50/60
102.7
Hz
Current
consump-
tion (A)
50/60
14.2
50/60
29.4
50/60
24.8
50/60
49.1
50/60
48.8
50/60
89.1
Hz
Current
consump-
tion (A)
60
14.2
60
29.4
60
24.8
60
49.1
60
48.8
60
89.1
Hz
Current
consump-
tion (A)
50/60
13
6 | Electrical connection
Power (kW) Fuse (A)
37.4
63
37.2
63
67.9
100
Power (kW) Fuse (A)
10.8
16
24.2
35
20.5
32
40.6
63
40.4
63
73.8
125
Power (kW) Fuse (A)
10.8
16
22.4
32
18.9
32
37.4
63
37.2
63
67.9
100
Power (kW) Fuse (A)
10.8
20
22.4
35
18.9
30
37.4
60
37.2
60
67.9
100
Power (kW) Fuse (A)
10.8
16
RCD type
B
B
B
RCD type
B
B
B
B
B
B
RCD type
B
B
B
B
B
B
RCD type
B
B
B
B
B
B
RCD type
B
65 / 108