15. RESECTION MEASUREMENT
821.492m
2 1
90' 00' 00"
1
HAR
0" 00' 00"
Sight Known Station
B
&&
:
Measurement start
Sight Known Station
C
&
: Measurement start
ZA
90" 00' 00"
HAR
62' 33' 40"
When the measurement has been
finished, the measured values are
displayed, and the display asks
whether you want t o observe the
second station (Known Station
B).
16) Sight the centre of the reflecting
prism of Known Station B cor-
rectly
,
and press
&
.
The measurement is started.
When the measurement has been
finished, the measured values are
displayed, and the display asks
whether you want t o observe the
third station (Known Station C).
17) Sight the centre of the reflecting
prism of Known Point C accu-
rately,
and press
&
.
The measurement is started.
When the measurement has been
finished, the measured values are
displayed. "Busy" will appear on
the display while the instrument
station coordinates are being cal-
culated.