9.2 Emergency stop according to EN 60204
NOTICE
DANGER
DANGER
ma_dr_f6-cu-k-inst-20144795_en
• Energy supply for the rotating field of the motor is interrupted (motor coasts
down).
• Use when monitoring for standstill is not required.
• Unintentional start-up of the motor is prevented.
• No galvanic isolation of the motor from the drive controller DC link.
The safety functions meet the requirements of performance level e
and
SIL
3
(IEC 61508
and
Safety functions protect persons from mechanical damage when project planning,
installation and operation are carried out properly.
What can the
STO
function do in relation to
Emergency stop
can be realised by the
voltage may still be applied.
Emergency stop
can only be realised in conjunction with a mains contactor that
switches off the mains voltage!
By using suitable safety switchgear, the STO function can achieve stop categories
0 and 1 according to
EN 60204-1
• Stop category 0
"uncontrolled stop", i.e. stop by immediately switching off the energy to the drive
elements.
• Stop category 1
"controlled stop", i.e. the energy to the drive elements is maintained to achieve
the stop. The energy is only interrupted when standstill is reached.
Emergency stop according to
modes of the drive module. Resetting emergency stop must not lead to uncon-
trolled start-up of the drive.
Automatic restart when STO is no longer triggered.
Unpredictable consequences for personnel and machine.
ü In order to comply with
a) Ensured by external measures that the drive restarts only after confirmation.
Motor coast in the event of a fault
Danger to persons
ü If there is a danger to persons after the motor control has been switched off by
STO:
a) Block access to the hazardous area.
b) Wait until the drive stops.
Jerking of the drive in the event of a fault
Danger to persons
ü In case of double malfunction it can lead to unwanted jerk. The rotation angle is
depending on the number of poles of the selected drive and the gear ratio.
a) Switch off the supply voltage before carrying out any work on the machine.
b) Await capacitor discharge time (min. 5 minutes). Measure DC voltage at the
terminals.
Calculation of the jerk:
Safety function STO | 9
IEC 62061
).
EN 60204-1
STO
function, because the mains
in the system ().
EN 60204-1
must be functional in all operating
EN
60204-1, observe the following:
(ISO 13849-1
)
?
41