Alarm-Out; Figure 26: Device - Alarm-Out Setup Screen - Eneo MPR-32R080200A User Manual

Multisignal hd video recorder, hd-tvi, ahd, 960h
Table of Contents

Advertisement

Digital Video Recorder

Alarm-Out

Figure 26: Device – Alarm-Out setup screen.
Highlighting the box beside Dwell Time and pressing the
button allows you to set the dwell time of the alarm output.
Dwell times range from 5 seconds to 30 minutes.
Each alarm output can be given its own title by highlighting Title... and pressing the
button. A virtual keyboard
appears allowing you to enter the title.
Check the Reverse Relay box to reverse the Alarm Output Type connected to the DVR rear panel (NO→NC).
You can add and edit alarm output schedules on this screen. Highlight the + and press the
button to add a
schedule. Highlighting the boxes under the Column heading and pressing the
button allows you to edit the
information in those boxes.
The Day box allows you to select the days that the alarm schedule will be active. The choices are: Sun, Mon, Tue,
Wed, Thu, Fri, Sat, M~F, Hol and All.
The Range box allows you to set the time that the alarm schedule will be active in 15-minute increments from 00:00
to 24:00.
The Mode box allows you to set how the alarm reacts during the scheduled time. When set to On, the Alarm-Out is
active during the scheduled time. When set to Event, the Alarm-Out is only active when there is an Event during the
scheduled time.
The Channels box allows you to set which alarm outputs will be active. You can also select the DVR's internal buzzer.
The
box allows you to delete an alarm output schedule. You will be asked to confirm whether or not you really wish
to delete the schedule.