5.1.

SELECTING THE VIDEO STANDARD

The RATE SELECT jumper J6, located at the top rear of the module, determines whether the module will
operate as a distribution amplifier with SMPTE 259M (143 to 540 Mb/s) or DVB-ASI video signals or with
SMPTE 310M (19.4 Mb/s) signals. The LOCK jumper J3 located at the front of the module also needs to
be set correctly.
RATE SELECT:
To set the module to operate with SMPTE 259M or DVB-ASI signals install the jumper
in the 259M position.
To set module to operate with SMPTE 310M signals install the jumper in the 310M position.
LOCK:
To set the module to operate with SMPTE 259M or DVB-ASI signals install the jumper
in the AUTO position.
To set module to operate with SMPTE 310M signals install the jumper in the AUX position.
5.2.
SELECTING WHETHER LOCAL FAULTS WILL BE MONITORED
BY THE GLOBAL FRAME STATUS
The FRAME STATUS jumper J27, located at the front of the module determines whether local faults (as
shown by the Local Fault indicator) will be connected to the 7700FR frame's global status bus.
FRAME STATUS: To monitor faults on this module with the frame status indicators (on the PS FRAME
STATUS LED's and on the Frame's Fault Tally output) install this jumper in the On
position. On Rev 1 and Rev A boards install the jumper. (default)
When this jumper is installed in the Off position local faults on this module will not be
monitored. On Rev 1 and Rev A boards remove the jumper and re-install it so that
only one side is connected.
5.3.

SETTING THE EQUALIZER WARNING THRESHOLD

The EQ trimpot R46 is used to set the threshold of the cable equalizer warning. The equalizer warning is
factory set to 250 meters of Belden 8281 cable, but may be adjusted for other cable types or cable
lengths. To adjust the cable equalizer warning threshold, connect a signal to the input of the DA using the
required length of cable. Adjust the trimpot slowly until the Equalizer warning LED comes on. You can
verify that the equalizer warning is operating correctly by removing a few meters of cable from the input.
The LED should go off.
7705EO SDI Electrical to Optical Converter, 19.4Mb/s or 143-540Mb/s
Revision 1.8
7700 MultiFrame Manual
7705EO - 9